kWh/kW - Year 1

The kilowatt-hour per kilowatt-year metric is the annual electric output in year one EOutputYear1 divided by the system capacity PSystemCapacity. For photovoltaic systems, the system capacity is the Array Power on the Array page. For concentrating solar power systems, the system capacity is the Rated Turbine Net Capacity on the Power Block page.

EQ_kwhkwyr1

Where,

EOutputYear1 (AC kWh/year)

The total annual electric generation in the first year of operation reported on the Metrics table, and in the year one column of the project cash flow.

PSystemCapacity (DC kW)

The system's rated capacity expressed in kilowatts (see table below).

The system capacity depends on technology being modeled. Note that Solar Advisor converts the capacity value to kW before using it in the calculation.

Table 39. Rated system capacity values for each technology.

Technology

System Capacity

Input Page

PV SAM Performance Models

Total Array Power (Wdc)

Array

PV PVWatts

DC Rating (kW)

PVWatts Solar Array

CSP Parabolic Trough

Rated Turbine Net Capacity (MWe)

Power Block

CSP Power Tower

Nameplate Capacity (MWe)

Power Cycle

CSP Dish Stirling

Total Capacity (kW)

Solar Field

Generic Fossil

Nameplate Capacity (kWe)

Fossil Plant