Hourly Output Data

ico-minus-16x16Displaying Hourly Output Data

When you run simulations in the "saving hourly data" mode, or after setting preferences to save hourly data as described below, Solar Advisor stores a set of hourly performance data in a text file. The model provides several options for viewing the hourly data:

In Windows, you can display hourly data in either Excel or DView directly from Solar Advisor.
In both Windows and Mac OS, you can export hourly data to comma-separated text files or to the clipboard.
In both Windows and Mac OS, you can open the simulation output data file directly in a text editor, spreadsheet program, or other software that can read tab-delimited text files.

The hourly data for all options is for the "base case" input data, or based on values of input variables visible on the input pages. Solar Advisor does not store hourly performance data for additional simulations for parametric or other analysis configurations that require multiple simulations.

Each time you run simulations, Solar Advisor stores data from the simulation in a .out file generated by the simulation engine. Solar Advisor displays a subset of the data from this file when you display the case summary data directly in Excel or DView, and when you export the case summary data to a file or the clipboard. You can open the .out file directly to see the complete set of hourly data generated by the simulation engine.

To view case summary data:

Click the Export and view data button to open the Export Data window, or

SS_Button-ExportViewData

Click an option on the Results menu.

SS_Menu-ResultsCaseSummary

To view the simulation data (Windows and Mac OS):

1.On the File menu, click Preferences.
2.In the SAM Preferences window, check Save TRNSYS hourly data, list, and log files.
3.Click SS_Button-Ellipses to specify an easy-to-find folder where you want Solar Advisor to save the files.
4.Click Close.
5.On the File menu, click Clear Cached Simulations.
6.Click Run.

SS_Button-Run

Solar Advisor saves the files in the folder you specified with the extension .out.

7.Open the file using any program that can read tab-delimited text files, such as Excel, DView, or a text editor.

The hourly data folder is named with the extension .out. The naming convention is technology.hourly.out:

Dish-Stirling systems: dish.hourly.out
Photovoltaic systems: pv.hourly.out
Parabolic trough systems: trough.hourly.out
Power Tower systems: tower.hourly.out
ico-minus-16x16Parabolic Trough Empirical Hourly Variable Descriptions

Table 37. Hourly data variable names and explanations for parabolic trough systems.

Variable name

Units

Description

E_dump

MW

solar electric generation in excess of power plant maximum output

E_gross

MW

gross total electric generation

E_min

MW

solar electric generation below minimum power plant output

E_net

MW

net electric energy production (gross parasitics)

E_parasit

MW

total parasitics for entire system

Epar_OffLine

MW

total offline parasitic losses

Epar_OnLine

MW

total online parasitic losses

Q_abs

W/m2

absorbed energy

Q_dni

MW

solar radiation incident on the collector

Q_dump

MW

the amount of energy dumped (in excess of turbine and storage)

Q_from_ts

MW

energy from thermal storage

Q_gas

MW

gas thermal energy Input

Q_hftFpHtr

MW

HTF freeze protection from auxiliary heater

Q_htfFPTES

MW

HTF freeze protection from thermal energy storage

Q_nip

W/m2

measured beam radiation

Q_SF(MW)

MW

solar field thermal output (availability factor not applied)

Q_to_PB

MW

energy to the power block

Q_to_ts

MW

energy to thermal storage

Q_ts_Full

MW

energy dumped because the thermal storage is full

Q_tur_SU

MW

the energy needed to startup the turbine

QSF_Abs

MW

absorbed energy for the solar field

QSF_HCE_HL

MW

receiver heat losses for the solar field

QSF_nipCosTh

MW

measured beam radiation cosine theta

QSF_Pipe_HL

MW

piping heat losses for the solar field

QTS_HL

MW

energy losses from thermal storage

TIME

none

hour of the year

TOUPeriod

none

time of use periods (1 through 6)

ico-minus-16x16Photovoltaic Systems  Hourly Variable Descriptions

Table 38. Hourly data variable names and explanations for photovoltaic systems.

Variable Name

Units

Description

ACPower

kW

AC power at inverter output, not derated

AmbTemp

°C

ambient temperature

CellTemp

°C

cell temperature

DCPower

kW

DC power at array output, not derated

GlobHozRad

kW/m2

global horizontal radiation

IncBeamRad

kW/m2

incident beam radiation

IncDiffRad

kW/m2

incident diffuse radiation

IncTotRad

kW/m2

incident total radiation

InvEff

none

inverter efficiency by hour

InvPartLoad

none

inverter part load efficiency by hour

TIME

none

hour of the year

Windspd

m/s

wind speed