To view the SCA / HCE page, click Parasitics on the main window's navigation menu. Note that for the Power Block page to be available, the technology option in the Technology and Market window must be Concentrating Solar Power - Parabolic Trough System. |
The Parasitics page displays parameters describing losses due to parasitic electrical loads, such as drive motors, electronic circuits, and pump motors. Solar Advisor includes a set of default parasitic parameters for a range of solar trough power systems. Choose a reference parasitic system option that is the same or similar to the system you are modeling. Solar Advisor will automatically adjust the total parasitic load to match the size of the solar field and power block in the system you are modeling.
The design point parasitic values are the maximum possible values for each parasitic loss category. Solar Advisor calculates the hourly parasitic loss value for each category during simulation based on the design point, the PF and F0-F2 coefficients, and the solar field thermal output and power block load in each hour, and reports them in the hourly results. The calculated parasitic loss values are never as high as the total design point parasitic losses.
For a more detailed description of the model, please download the CSP trough reference manual from the Solar Advisor website's support page: https://www.nrel.gov/analysis/sam/support.html.
Contents |
||||
|
The values of input variables on the Parasitics page are stored in a library of reference solar fields. You can change the parameter values without changing the values stored in the library. For information about libraries, See Working with Libraries.
Parasitic Electric Energy Use
|
Equations for Calculated Values
Each parasitic loss type has a set of parameters that includes a factor, PF and F0, F1, and F2 coefficient. The design point values are maximum values and are calculated using the factor and PF coefficient. Solar Advisor uses the F0-F2 coefficients in calculations for the hourly simulations, which are described in the reference manual.
Table . Design point parasitic loss equations for each parasitic loss category.
Source of Parasitic Loss |
Equation |
SCA Drives and Electronics |
Factor x PF x Solar Field Area |
Solar Field HTF Pumps |
Factor x PF x Solar Field Area |
TES Pumps |
Factor x PF x Gross Turbine Output |
Antifreeze Pumping |
Factor x Solar Field HTF Pump losses |
Power Block Fixed |
Factor x Gross Turbine Output |
Balance of Plant |
Factor x PF x Gross Turbine Output |
Heater and Boiler |
Factor x PF x Gross Turbine Output |
Cooling Towers |
Factor x PF x Gross Turbine Output |
The Total Design Point Parasitics is the sum of the the design point parastic loss categories:
| • | SCA Drives and Electronics |
| • | Solar Field HTF Pumps |
| • | TES Pumps |
| • | Power Block Fixed |
| • | Balance of Plant |
| • | Heater and Boiler |
| • | Cooling Towers |